Industrial Switches Manufacturer · 25 Years of Expertise

Layer 2 vs Layer 3 Industrial Switch: Which One Does Your Network Need?

A packaging machine with one PLC, one HMI, several drives, and a local engineering port may never need routing inside its control cabinet. A factory with multiple production cells, SCADA servers, wireless systems, cameras, and links to an operations center probably does.

That difference is more useful than the usual shorthand that Layer 2 is “basic” and Layer 3 is “advanced.” The real question is where traffic must cross an IP subnet boundary, where policy must be enforced, and how much of the plant should remain in one broadcast domain.

This guide compares Layer 2 vs Layer 3 industrial switches from that design perspective. It explains VLANs, inter-VLAN routing, Layer 3 switches versus routers and firewalls, and the hybrid architecture used in many scalable industrial networks.

Quick answer: Use a Layer 2 industrial switch when connected devices mainly communicate within the same VLAN or subnet and another device can handle any required routing. Use a Layer 3 industrial switch where the switching infrastructure must route traffic between VLANs or subnets. Many plants use both: Layer 2 at the machine or cell edge, Layer 3 at the aggregation layer, and a firewall or secure gateway at trust boundaries.

Layer 2 vs Layer 3 industrial switch complete guide infographic covering forwarding decisions, VLAN routing, hybrid architecture, industrial design factors, selection steps and Maisvch product mapping

Editor’s notes: Layer 2 vs Layer 3 Industrial Switch Selection Framework. For educational reuse, credit Maisvch and link to this guide.

Layer 2 vs Layer 3 Industrial Switch at a Glance

Decision point Layer 2 industrial switch Layer 3 industrial switch
Main forwarding decision Destination MAC address Destination MAC address for local switching; destination IP address for routed traffic
Typical network scope One or more VLANs without local inter-VLAN routing Multiple VLANs or IP subnets with local routing
VLAN support Available on managed Layer 2 models Commonly available, plus routing between configured VLAN interfaces
Inter-VLAN communication Requires a router, firewall, gateway, or upstream Layer 3 switch Can be performed by the switch when the required routing feature is configured
Common industrial role Machine, control cabinet, production cell, field access Cell/area aggregation, plant backbone, multi-building or multi-subnet network
Routing table No user-traffic routing table on a pure Layer 2 switch Static routes and/or dynamic routing, depending on the model
Security role Separates VLANs but does not route between them May apply Layer 3 ACLs, but is not automatically a firewall
Cost and configuration Usually lower and simpler for local networks Usually higher, with more design and configuration responsibility

These are functional distinctions, not promises about a specific product. Port speed, switching capacity, routing throughput, ACL scale, multicast features, redundancy protocols, and environmental ratings must all be verified at model level.

Watch the Video: Layer 2 vs Layer 3 Networking in 105 Seconds

Before examining switch functions and industrial network architectures in detail, this short Maisvch Network Essentials video explains how Layer 2 switches use MAC addresses for local delivery, while Layer 3 devices use IP addresses to route traffic between networks.

What Does a Layer 2 Industrial Switch Do?

A Layer 2 switch forwards Ethernet frames within a local Layer 2 domain. It learns which source MAC addresses appear on which ports and builds a MAC address table. When a frame arrives, the switch uses the destination MAC address to select the appropriate outgoing port. Broadcasts and some unknown or multicast traffic may be flooded within the relevant VLAN according to the switch configuration.

The phrase “within the relevant VLAN” matters. A managed Layer 2 switch can divide one physical switch into multiple logical Layer 2 networks using VLANs. Each VLAN is a separate broadcast domain, but the switch does not route ordinary user traffic from one VLAN to another.

A Layer 2 industrial switch may still support substantial management and resilience features, including:

  • IEEE 802.1Q VLANs and tagged trunks;
  • spanning tree or industrial ring redundancy;
  • link aggregation;
  • Quality of Service (QoS);
  • IGMP snooping for multicast control;
  • port mirroring and cable diagnostics;
  • SNMP, alarms, event logs, and secure management;
  • access controls such as port security or MAC filtering.

Feature support varies. Layer 2 does not mean unmanaged, and it does not mean unsuitable for a critical network. A well-specified managed Layer 2 switch is often the correct access-layer device for a machine, production cell, camera cluster, or wireless edge.

What Does a Layer 3 Industrial Switch Do?

A Layer 3 industrial switch combines Layer 2 Ethernet switching with IP forwarding. It can switch frames inside a VLAN and route packets between configured IP subnets.

In a common design, each VLAN has a logical Layer 3 interface on the switch. This is often called a switched virtual interface (SVI) or routed VLAN interface (RVI), although terminology differs among platforms. End devices in that VLAN use the interface IP address as their default gateway. When traffic is destined for another subnet, the switch consults its routing table and forwards the packet toward the next hop or directly connected VLAN.

Layer 3 capability can include:

  • directly connected and static routes;
  • inter-VLAN routing;
  • routed physical ports;
  • dynamic routing protocols such as RIP or OSPF;
  • Layer 3 access control lists;
  • gateway redundancy or multicast routing features.

None of these should be assumed from the words “Layer 3” alone. Some products provide only static routing and a small number of interfaces. Others support dynamic routing and larger tables. The datasheet and management manual should define exactly what is implemented, at what scale, and under which software version.

Managed Does Not Mean Layer 3

This is one of the most common sources of selection errors.

A managed switch can be configured and monitored. It may support VLANs, QoS, redundancy, diagnostics, and secure administration while remaining a Layer 2 forwarding device. Its management IP address allows an engineer to reach the switch itself; that address does not prove that the switch can route production traffic between subnets.

A Layer 3 switch has IP forwarding capability in addition to Layer 2 switching. In practice it is normally managed, because routing must be configured, but the two labels answer different questions:

Label Question it answers
Managed or unmanaged Can the switch be configured and monitored?
Layer 2 or Layer 3 Can the switch route user traffic between IP networks?

When reviewing a quotation, look for explicit routing functions rather than relying on “managed,” “smart,” or “Layer 2+” in the product name.

VLANs and Inter-VLAN Routing: The Boundary That Decides

VLANs are a Layer 2 mechanism. The IEEE 802.1Q standard for bridges and bridged networks specifies bridged networks and virtual LANs. A managed Layer 2 switch can therefore create and carry multiple VLANs without being able to route between them.

Suppose a plant uses:

  • VLAN 10 for PLCs and remote I/O;
  • VLAN 20 for HMIs and engineering stations;
  • VLAN 30 for IP cameras;
  • VLAN 40 for industrial wireless access points;
  • VLAN 50 for switch management.

Devices within one VLAN can communicate through Layer 2 switching, subject to their IP settings and any port controls. Traffic from VLAN 10 to VLAN 20 needs a Layer 3 forwarding point. Where that forwarding occurs is an architectural choice.

Option 1: Route through a firewall or secure gateway

The VLAN trunks terminate at a firewall or security gateway, which becomes the default gateway and policy enforcement point. This is useful when traffic crosses a meaningful trust boundary and requires stateful inspection, detailed logging, application-aware controls, VPN services, or stronger separation.

The tradeoff is that inter-VLAN traffic must traverse the firewall path. Interface capacity, aggregate throughput, availability, and rule management must be sized for the expected flows.

Option 2: Route on a Layer 3 aggregation switch

The Layer 3 switch hosts the VLAN interfaces and routes permitted traffic locally. This can keep high-volume, trusted east-west traffic on the plant backbone instead of sending it to an external routing device and back.

Local routing is not automatically the best security choice. If two zones require inspection, routing them directly on the switch may bypass the firewall. Layer 3 ACLs can provide basic source, destination, and protocol filtering when supported, but they should not be described as equivalent to a stateful industrial firewall.

Option 3: Use a separate router over a VLAN trunk

A Layer 2 switch can carry several VLANs over one tagged link to a router or firewall, sometimes called “router-on-a-stick.” This is practical for a small site with modest inter-VLAN traffic, but the shared trunk and routing device become important capacity and availability points.

The correct location for routing follows the traffic and security requirements. It should not be chosen simply because one device has a checkbox labeled “IP routing.”

When a Layer 2 Industrial Switch Is Enough

Layer 2 is usually sufficient when most or all of the following are true:

  • The switch connects devices that should remain in the same production-cell VLAN.
  • Communication is primarily local, such as PLC-to-I/O, PLC-to-HMI, or controller-to-drive traffic.
  • The number of endpoints and broadcast load are controlled.
  • Any connection to SCADA, historians, remote engineering, or another cell can be routed upstream.
  • The site already has a suitable firewall, router, or Layer 3 aggregation switch.
  • The project needs VLANs, QoS, multicast filtering, diagnostics, and redundancy but not local IP routing.
  • Operations staff would benefit from a smaller configuration and troubleshooting surface.

Consider a compact machine network with one PLC, one HMI, eight drives, and a maintenance port. If all devices belong to one control subnet and only a small amount of traffic leaves through an upstream gateway, adding Layer 3 routing inside the cabinet may create cost and configuration work without solving a real problem.

Layer 2 can also be the better security choice at the edge. When the access switch cannot route between VLANs, inter-zone traffic is forced toward the designated Layer 3 or security boundary rather than taking an unintended local path.

When a Layer 3 Industrial Switch Is Justified

A Layer 3 industrial switch becomes useful when the network has a clear need to route at the switching layer.

Multiple production cells or process areas

Large plants often assign a subnet or VLAN to each line, cell, building, or operational function. A Layer 3 aggregation switch can connect those subnets and advertise summarized or specific routes toward the wider OT network, depending on the design.

Significant traffic between trusted VLANs

SCADA servers, historians, engineering workstations, wireless controllers, video systems, and edge-computing platforms may exchange traffic across several subnets. If those flows are trusted and do not require firewall inspection, local Layer 3 forwarding can avoid an unnecessary external path.

This does not guarantee lower latency or full-rate routing on every product. Routing performance, packet size, enabled features, and hardware architecture are model-specific and should be tested against the traffic profile.

A routed plant backbone

Routing can limit the geographic spread of Layer 2 faults and broadcasts. It can also support more explicit path selection across buildings or process areas. The benefit is strongest when the design has a deliberate IP addressing plan, documented route ownership, and people able to troubleshoot it.

More than one route to important networks

Static or dynamic routing may be needed when a site has redundant aggregation paths, multiple upstream gateways, or several remote networks. The exact protocol and convergence requirement must be matched to the switch. “Supports OSPF” is not enough on its own; verify route scale, areas, authentication options, timers, redistribution behavior, and failover testing relevant to the project.

Growth has made centralized routing a bottleneck

A small Layer 2 network can grow into dozens of VLANs and large east-west flows. Moving selected gateways to a Layer 3 aggregation switch may reduce load on a central router or firewall. Before doing so, document which flows will no longer pass through the security device and recreate any required policy at the correct boundary.

The Hybrid Architecture Most Industrial Networks Actually Need

The Layer 2 versus Layer 3 decision is rarely one device type for the entire plant. A practical hierarchy assigns each function to the layer where it is useful.

Layer 2 Layer 3 Industrial Network Architecture
Hybrid industrial network architecture: use Layer 2 switching inside production cells, Layer 3 routing where subnets meet, and a firewall or secure gateway where trust changes.
Network position Typical switch role Why
Machine or cabinet Unmanaged or managed Layer 2 Local connectivity with minimum unnecessary complexity
Production cell Managed Layer 2 VLANs, QoS, multicast control, diagnostics, and link redundancy
Area or building aggregation Managed Layer 3 Inter-subnet routing, route control, higher-density fiber or high-speed uplinks
OT/IT or external boundary Firewall, secure router, or gateway Trust enforcement, inspection, logging, VPN, NAT, or WAN functions as required

The table is a starting pattern, not a mandatory hierarchy. A small wastewater site may route at one central firewall. A large automotive plant may use Layer 3 at several aggregation points. A power or transportation network may follow sector-specific architectures and redundancy requirements.

Industrial Design Factors That Generic Comparisons Miss

Generic office-network comparisons often stop at MAC versus IP. Industrial selection has additional consequences.

1. Control flows and failure domains

Map who actually communicates with whom before creating VLANs or routes. A PLC and its remote I/O may need to remain in the same local domain, while SCADA polling, historian uploads, and engineering access cross Layer 3 boundaries.

Smaller Layer 2 domains can contain broadcasts and some faults, but excessive segmentation can also introduce gateways into traffic paths that were previously local. The design should follow the control system’s supported topology, not an arbitrary device-count rule.

2. Broadcast, multicast, and discovery traffic

VLANs contain Layer 2 broadcasts. Routers do not forward ordinary Layer 2 broadcasts between subnets by default. Some industrial discovery, commissioning, redundancy, or control mechanisms rely on broadcast or multicast behavior, so a protocol that works inside one VLAN may not work unchanged across a routed boundary.

IGMP snooping is a Layer 2 multicast-control feature. Multicast routing between subnets is a separate Layer 3 capability and may require additional protocols and configuration. Verify the industrial protocol, controller, switch, and routing behavior together.

3. Segmentation is not the same as security enforcement

VLANs create logical separation, but they do not decide whether routed traffic should be trusted. The NIST Guide to Operational Technology Security, SP 800-82 Rev. 3 discusses physical and logical network segmentation for OT and the use of gateways and firewalls to enforce permitted communications between segments.

For each pair of zones, decide whether traffic may be routed directly, restricted with switch ACLs, or inspected by a firewall. Place management interfaces in a controlled network, use secure management protocols where supported, and document the allowed data flows before commissioning.

4. Redundancy exists at both layers

Layer 2 networks may use STP/RSTP/MSTP, link aggregation, or vendor-specific industrial ring protocols. Routed networks may use redundant gateways, static failover, or dynamic routing. These mechanisms solve different failure cases and have different recovery behavior.

Do not select solely by the shortest recovery time printed in a brochure. Test link loss, switch loss, power loss, uplink restoration, route reconvergence, multicast recovery, and the resulting effect on PLC or supervisory sessions.

5. Layer 3 does not make Ethernet deterministic

Routing can improve architecture and traffic containment, but it does not by itself guarantee bounded latency, zero packet loss, time synchronization, or deterministic control. QoS, bandwidth engineering, congestion management, time-aware functions, endpoint behavior, and the industrial protocol still matter.

Two Industrial Topology Examples

The following are design examples, not customer case studies. Their purpose is to show how the decision changes with traffic scope.

Example A: One packaging cell

Endpoints:

  • one PLC and local HMI;
  • distributed I/O and drives;
  • one vision station;
  • one maintenance laptop connection;
  • one uplink to the plant network.

The controller, HMI, and field devices communicate mainly inside one cell subnet. A managed Layer 2 industrial switch can provide local forwarding, VLAN assignment, QoS, multicast control, diagnostics, and redundancy as required. The upstream firewall or aggregation switch routes the limited traffic destined for SCADA or engineering services.

Likely choice: Layer 2 at the cell, provided bandwidth, protocol, environmental, and recovery requirements are met.

Example B: A multi-line plant with central SCADA

Endpoints and systems:

  • separate VLANs for several production lines;
  • SCADA and historian servers in an operations zone;
  • engineering workstations in a controlled support zone;
  • camera and industrial WiFi networks;
  • redundant fiber links between buildings;
  • an OT/IT boundary firewall.

Managed Layer 2 switches connect local endpoints in each line. Layer 3 industrial switches aggregate the line VLANs and route selected trusted plant traffic. Traffic crossing the OT/IT boundary or another security zone passes through the firewall. Cameras, wireless, and control traffic can be separated by VLAN and policy while sharing the physical backbone.

Likely choice: a hybrid design, with Layer 2 at access and Layer 3 at aggregation. The routing and firewall policy should be developed from an approved traffic-flow matrix.

Can a Layer 3 Switch Replace a Router or Firewall?

Sometimes it can replace a router used only for internal inter-VLAN forwarding. It should not be assumed to replace every router or any firewall.

Function Layer 3 switch Router Firewall
Switching within a VLAN Yes Not its primary role Not its primary role
Routing between internal VLANs Yes, when supported Yes Yes, when configured
Static or dynamic routing Model-specific Common, model-specific Model-specific
WAN or carrier connectivity Usually limited Common Sometimes
NAT Not inherent; model-specific Common Common
Site-to-site or remote-access VPN Not inherent; model-specific Often available Often available
Stateful inspection and threat controls Not a standard Layer 3 switch function Limited or model-specific Primary role
Layer 3 ACLs Model-specific Common Policy model is broader than basic ACLs

The overlap is real, but so are the differences. Use the product’s documented functions and the site’s security architecture, not the device label, to assign each role.

What Does “Layer 2+” Mean?

“Layer 2+” is not a precise standardized capability class. It commonly describes a managed Layer 2 switch with selected Layer 3 functions, often static routing, but the implementation varies by manufacturer and product family.

For any Layer 2+ product, verify:

  • whether it can create routed VLAN interfaces;
  • whether it supports IPv4, IPv6, or both;
  • the number of static routes and Layer 3 interfaces;
  • whether routed physical ports are available;
  • whether dynamic routing is supported;
  • ACL type and scale;
  • multicast-routing capability;
  • routing throughput and supported packet sizes;
  • redundancy and management functions.

If the requirement says “Layer 3,” translate it into this feature list before comparing quotations.

How to Choose: A Seven-Step Engineering Process

Step 1: Draw the traffic flows

List sources, destinations, protocols, data rates, direction, criticality, and whether each flow must cross a trust boundary. Include normal operation, engineering access, backups, firmware updates, alarms, video, and time synchronization.

Step 2: Define VLANs, subnets, and security zones

Group devices by process function, location, risk, and communication need. Do not create one VLAN per device type without checking the resulting traffic paths. Record the IP plan and default gateway for every subnet.

Step 3: Decide where inter-VLAN routing belongs

For each cross-VLAN flow, choose a Layer 3 switch, router, firewall, or gateway. Flows that require inspection should traverse the security control. High-volume trusted internal flows may be candidates for local Layer 3 forwarding.

Step 4: Specify routing functions

State whether the project needs only connected routes, static routes, or a dynamic protocol. Define IPv4/IPv6 requirements, route count, VLAN interface count, route summarization, redundancy, convergence, ACLs, and multicast behavior.

Step 5: Calculate Layer 2 and Layer 3 capacity

Check port speed, uplink oversubscription, switching capacity, forwarding rate, MAC table size, VLAN scale, routing-table size, ACL entries, and multicast groups. Do not use switching capacity as a substitute for verified Layer 3 performance.

Step 6: Add industrial requirements

Confirm power input, redundant power behavior, operating temperature, fanless design, EMC immunity, surge protection, vibration and shock ratings, ingress protection, mounting, connector type, fiber budget, and project-specific certifications.

Step 7: Test the failure cases

Build a representative pilot. Verify VLAN isolation, allowed routes, blocked routes, firewall paths, protocol discovery, multicast, management access, congestion behavior, and recovery after cable, power, switch, and upstream-gateway failures.

Layer 2 vs Layer 3 Industrial Switch Selection Checklist

Requirement What to verify
Network role Machine, access, cell, area aggregation, core, or security boundary
VLAN design VLAN count, tagged and untagged ports, trunk behavior, VLAN scale
Routing Connected, static, RIP, OSPF, or other required protocols; IPv4/IPv6 support
Interfaces Number of SVIs/RVIs and routed physical ports
Scale MAC addresses, ARP/neighbor entries, routes, ACL entries, multicast groups
Performance Switching capacity, forwarding rate, Layer 3 throughput, packet-size conditions
Multicast IGMP snooping at Layer 2; multicast routing only if required and supported
Security Management security, ACLs, authentication, logging, and firewall path
Resilience Ring or spanning-tree functions, link aggregation, gateway/routing failover
Uplinks Copper/fiber type, 1G/10G rate, SFP/SFP+ compatibility, optical budget
Environment Temperature, EMC, surge, vibration, shock, humidity, ingress, fanless operation
Installation DIN rail, rack, wall, embedded, cabinet dimensions, grounding and power
Compliance Exact standards, test reports, and approvals required by the project
Operations CLI, web, SNMP, alarms, configuration backup, firmware and support lifecycle

Where Maisvch Layer 2 and Layer 3 Switches Fit

Maisvch has 25 years of experience in industrial communication and offers both industrial Layer 2 switches and industrial Layer 3 switches.

The current Layer 2 category includes unmanaged, simply managed, and managed options across the MIEN and MISCOM families. Maisvch identifies MIEN2XXX and MIEN3XXX as unmanaged 100 Mbps and Gigabit families, MIEN5XXX as a simply managed family, and MISCOM6XXX and MISCOM7XXX as managed Layer 2 families. Port mix, management functions, temperature, redundancy, and certifications still need to be checked on the selected model.

For routing and aggregation, the current Layer 3 category includes MISCOM8XXX products with Gigabit and 10G interfaces and CLI, web, and SNMP management. As one specific example, the official page for the MISCOM8028GX-4XGF-16GF-8GC lists four 10G SFP+ ports, sixteen 1G SFP ports, eight 1G combo ports, static routing, RIP v1/v2, and OSPF. Its page also lists STP/RSTP/MSTP and industrial ring options, redundant power configurations, an IP40 fanless enclosure, and an operating range of -40 to +70 degrees C.

That example should not be generalized to every MISCOM8XXX model. Verify the exact port arrangement, software features, environmental rating, power option, and certification against the current datasheet before specifying a product.

For projects that are still at the architecture stage, the complete industrial Ethernet switch guide provides a broader framework for choosing management, ports, fiber, PoE, redundancy, and environmental specifications.

Decision Matrix: Which One Does Your Network Need?

Your situation Likely starting point
One machine or cell, one subnet, mostly local traffic Layer 2 industrial switch
Several VLANs, all routing handled by an existing firewall Managed Layer 2 industrial switch
Several cells feed a central aggregation point Layer 2 access plus Layer 3 aggregation
High-volume trusted traffic must move between local VLANs Layer 3 at aggregation, after security review
Traffic crosses a safety, operational, vendor, or IT/OT trust boundary Route through an appropriate firewall or secure gateway
Multiple buildings or remote subnets need route control Layer 3 industrial switch or industrial router, based on interfaces and services
The only reason for choosing Layer 3 is that it sounds more future-proof Revisit the traffic map and buy only the functions the design can justify

Frequently Asked Questions

Can a Layer 2 switch support VLANs?

Yes. Managed Layer 2 switches commonly support IEEE 802.1Q VLANs and tagged trunks. VLAN support does not prove that the switch can route between those VLANs.

Can devices in different VLANs communicate through a Layer 2 switch?

Not through Layer 2 forwarding alone. Their traffic must reach a Layer 3 device, such as a Layer 3 switch, router, firewall, or gateway, that has an interface and route for both networks and permits the communication.

Can a Layer 3 switch also work as a Layer 2 switch?

Generally, yes. A Layer 3 switch normally provides Layer 2 switching as well as routing. Check the configuration model and feature limits of the exact product.

Is every managed switch a Layer 3 switch?

No. A managed Layer 2 switch can have an IP address for administration and support VLANs, QoS, SNMP, diagnostics, and redundancy without routing user traffic between subnets.

Is a Layer 3 switch faster than a Layer 2 switch?

Not as a universal rule. Products differ in switching silicon, port rates, forwarding capacity, packet-size performance, and enabled features. A Layer 3 switch can make inter-VLAN forwarding more direct in some architectures, but the actual result must be verified against the model and topology.

Does a Layer 3 switch replace a firewall?

No. It may support ACLs and route between VLANs, but a standard Layer 3 switch does not inherently provide stateful inspection, threat prevention, VPN, NAT, or the policy visibility expected from a firewall.

Do I need a Layer 3 switch at every production cell?

Usually not. If cell devices communicate locally and an upstream device handles routing, managed Layer 2 access switches may be sufficient. Add Layer 3 where routing at that location solves a documented traffic, scale, or resilience requirement.

Which switch is better for SCADA networks?

Neither layer is universally better. A small SCADA site may use Layer 2 access and one secure routing boundary. A multi-area system may need Layer 3 aggregation between well-defined subnets. Availability, protocol behavior, traffic flows, security zones, and environmental requirements should drive the choice.

Does Layer 3 improve industrial WiFi or AGV roaming?

Not by itself. Routing determines how traffic moves between subnets. Roaming performance depends on the WLAN architecture, AP coverage and overlap, radio planning, authentication, client behavior, and controller features. Keeping a mobile client in one appropriately designed VLAN may avoid an IP-subnet change during roaming, but the final WLAN design must be validated end to end.

Final Recommendation

Choose the network role before choosing the switch label.

If traffic stays inside a machine or production-cell subnet, a Layer 2 industrial switch can provide robust local connectivity without unnecessary routing complexity. If the plant needs to route between multiple VLANs, aggregate several process areas, or maintain explicit paths to remote subnets, a Layer 3 industrial switch may be the right tool. Where traffic crosses trust boundaries, keep the firewall or secure gateway in the path.

The most scalable answer is often a combination: Layer 2 at the industrial edge, Layer 3 where subnets meet, and security controls where trust changes. To review a Maisvch option, send the topology, traffic-flow list, VLAN and subnet plan, uplink requirements, environmental conditions, and required routing features to [email protected].

You might also like ...