Industrial Switches Manufacturer · 25 Years of Expertise

MW-IOD0808 8DI/8DO Modbus RS232/485 Remote I/O

8×Digital Inputs, 8×Digital Outputs, 1×RS232/485 Serial Port

Features and Benefits
  • Eight digital inputs: PNP wet-contact inputs accept 5–24 VDC signals, with 12 VDC rated input voltage and 500 VAC optocoupler isolation.
  • Eight relay outputs: Dry-contact relays are rated at 10 A at 250 VAC or 30 VDC per contact; DO1–DO4 use 3-terminal contacts and DO5–DO8 use 2-terminal contacts.
  • RS232 or RS485 serial interface: One isolated serial interface is available as RS232 or RS485 and supports 600–460800 bps. RS485 termination can be enabled with an internal jumper.
  • Defined Modbus RTU operations: The module operates as a Modbus RTU slave and supports function code 02 for DI and function codes 01, 05, 15 and 16 for DO.
  • Digital input processing: Configurable input filtering and rising-edge, falling-edge or both-edge counting support stable state acquisition and event counting.
  • Flexible relay control: Configure DO power-up states and output hold timing, issue momentary close or open commands to one or multiple outputs, or run cyclic switching on one output at a configured frequency.
  • Configuration and maintenance: Read device information, restart the device, restore factory settings or upgrade firmware online. Remote I/O configuration software assists commissioning and configuration.
  • Industrial installation: A reverse-polarity-protected 9–36 VDC input, −40°C to +85°C operating range, and 35 mm DIN-rail or wall mounting support industrial installations.

The Maisvch MW-IOD0808 is a Modbus RTU remote I/O module for monitoring eight digital input states and controlling eight relay outputs from a Modbus RTU master. It provides one RS232 or RS485 serial interface, with baud rates from 600 bps to 460800 bps.

The module provides input filtering and edge counting, configurable relay power-up states and output hold timing, momentary close or open commands, and cyclic switching at a configured frequency. Device information, online restart, factory reset and firmware upgrade functions are available, and remote I/O configuration software supports commissioning and configuration. A 9–36 VDC input, −40°C to +85°C operating range, and 35 mm DIN-rail or wall mounting suit industrial automation, building automation, environmental monitoring, energy management, safety monitoring and industrial IoT installations.

Software
Management Function Support Modbus RTU protocol, Slave address (1-247) setting and reading

Support Modbus function codes 01, 02, 03, 04, 05, 06, 15, 16

Support DI status reading, DI input filtering, DI counting.

Supports DO status reading and control, DO power-on initial state setting, DO output delay hold

Support serial port parameter reading and setting

Support device information reading

Support online reboot, factory reset, device upgrade.

Support remote IO configuration software management

Interface
Serial Port Serial port type: 1 RS232 or RS485 optional

Connection: 6-position 5mm pitch terminal block

Baud rate: 600bps~460800bps

Data bit: 8bit

Stop bit: 1bit, 2bit

Check digit: None, Odd, Even

Isolation voltage: 500VDC

DI Number of channels: 8 digital inputs

Connection: 10-position 5mm pitch terminal block

Modbus function code: 02, 03, 04, 16

Rated voltage: DC12V (DC5~24V)

Input Type: Wet contact PNP (Logic level 0: No external power input;

Logic level 1: with DC5~24V external power input)

Isolation protection: 500VAC (optocoupler isolation)

DO Number of channels: 8 digital outputs (DO1-DO4 are 3-contact relays, DO5-DO8 are 2-contact relays)

Connection: 20-position 5mm pitch terminal block

Modbus function code: 01, 03, 04, 05, 15Output type: relay output (dry contact)

Contact rated load: 10A@AC250V, 10A@DC30V

Initial insulation resistance: 1000MΩ (min.) @500VDC

Contact resistance: ≤100mΩ

Electrical life: 100,000 operations (rated load)

Isolation protection: 500VAC

Button One-click restart, factory reset
Status LED Operation, DO status
Power Supply
Input Voltage DC9~36V
Power Consumption <3.5W@DC24V(full load)
Connection 2-position 5mm pitch terminal block
Protection Anti-reverse
Physical Characteristics
Dimensions 145×90×40 mm (Not including DIN rail mounting clip or connectors)
Installations 35mm DIN Rail mounting or wall mounting
Shell Plastic
Weight 0.25kg
Working Environment
Operating Temp -40℃~+85℃
Storage Temp -40℃~+85℃
Relative Humidity 5%~95%(non-condensing)
Industry Standard
EMC IEC 61000-4-5(Surge): Level 3
datasheet
MW-IOD0808 Datasheet MW-IOD0808-datasheet V1.0
Standard Model RS232/485 DI DO Input Voltage
MW-IOD0808 1 8 8 DC9~36V