MWE485-HUB4 4*RS232/485/422 Full-isolation HUB Converter

Features and Benefits
  • Support conversion between one master station RS232/485/422 and 4 slave stations RS232/485/422
  • Support auto-sensing baud rate 300bps to 115200bps
  • Support separate optical isolation between the master/slave and slave/slave stations
  • Support auto recognition of RS485 data flow direction and 0 delay auto forwarding
  • Comprehensive fault-tolerant mechanism, one node damage does not affect other nodes
  • Support 15kV static protection and 600W/ms lightning protection
  • Support 4×128 nodes multi-machine communication
  • Support DC5V power input
  • Support working temperatures from -40 ℃ to +85 ℃

The MWE485-HUB4 is a serial port full-isolation hub converter that supports bidirectional transparent conversion between one RS232/485/422 master station and 4 RS232/485/422 slave stations. It can improve the RS485 bus structure, increase the load capacity and transmission distance of RS485. It supports DC5V power input and wall-hanging installation method to meet the needs of various industry.It provides a RS-485 star connection mode, which can bring great convenience to network layout. The fanless and low-power hardware design supports a wide temperature range of -40 ℃ to+85 ℃, suitable for various harsh industrial environments. It can be widely used in indoor and outdoor serial field-bus systems.

Interface
Serial Port Standard: Compliant with EIA RS232,RS485 and RS422 standards

Number of port: 1 master station RS232/485/422 and 4 slave stations RS232/485/422

RS232/485/422 signal pins: TX+, RX+, TX-, RX-, GND, TX, RX

Baud rate: 300bps~115200bps

Communication distance: 1.2km (9600bps), the higher the rate, the shorter the distance

Load capacity: Each RS485/422 station supports 128 nodes polling

Direction control: RS485 data flow direction auto recognition, zero delay auto forwarding

Connection method: DB9M

Port protection: 15kV static protection and 600W/ms lightning protection

Optical isolation: 2.5kV between the master/slave and slave/slave stations

Status LED Power LED, data sending LED, data receiving LED
Power Supply
Power Input DC5V
Working Current <2W@DC5V
Connection DC circular socket
Physical Characteristics
Dimensions 214×92×29(mm)(including mounting brackets)
Installation Wall mount
Weight About 0.5kg
Working Environment
Operating Temp -40℃~+85℃
Storage Temp -40℃~+85℃
Relative Humidity 5%~95% (non-condensing)
datasheet
MWE485-HUB4 Datasheet MWE485-HUB4-Datasheet-V1.0-260105 V1.0
Standard Model Master Station RS232/485/422 Slave Station RS232/485/422 Power Voltage
MWE485-HUB4 1 4 DC5V